Designing of Digital Ammeter is basically a process of converting a voltmeter into Ammeter. We know that V=I x R. From this we can say that Voltage drop across resistor (shunt) is directly proportional to the current (V = I). In ammeter this resistance is called Shunt. Shunt resistance have very small value and it will not affect the load voltage. Most commonly 75mV shunts are available in market. Or you can use low value resistance. Continue reading DC Current Measurement using Shunt Resistor